Renewable Design for Power Supply 30v - DC 12V24V 600W Dual Output SMPS Power Supply – Huyssen
Renewable Design for Power Supply 30v - DC 12V24V 600W Dual Output SMPS Power Supply – Huyssen Detail:
Features:
- Huyssen Daul Output Voltage Power Supply
- AC input :90-132V /175-264V
- Cooling by fan
- All using 105°C long life electrolytic capacitors
- High operating temperature up to 70°C
- High efficiency, long life and high reliability
- LED indicator for power on
- Full load high temperature burn-in, 100% burn-in test
- Protections: Short circuit / over current / Overload / Over voltage
- 24 months warranty
Specifications:
|
MODEL |
HSJ-600-2412 |
HSJ-600-3612 |
HSJ-600-4824 |
||||
| OUTPUT | OUTPUT NUMBER |
CH1 |
CH2 |
CH1 |
CH2 |
CH1 |
CH2 |
| DC VOLTAGE |
12V |
24V |
36V |
12V |
48V |
24V |
|
| RATED CURRENT |
10A |
20A |
15A |
5A |
6A |
13A |
|
| RATED POWER |
600W |
600W |
600W |
||||
| RIPPLE&NOISE |
120mVp-p |
240mVp-p |
300mVp-p |
120mVp-p |
400mVp-p |
240mVp-p |
|
| VOLTAGETOLERANCE |
±2.0% |
±6.0% |
±2.0% |
±5.0% |
±4.0% |
±4.0% |
|
| LINEREGULATION |
±0.5% |
±1.5% |
±0.5% |
±1.0% |
±0.5% |
±0.5% |
|
| LOADREGULATION |
±0.5% |
±3.0% |
±0.5% |
±2.0% |
±3.0% |
±3.0% |
|
| SETUP.RISEHOLD.TIME | 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load | ||||||
| HOLD TIME | 80ms/230VAC 16ms/115VAC at full load | ||||||
| INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | |||||
| FREQUENCYRANGE | 47~63HZ | ||||||
| EFFICIENCY |
84% |
85% |
87% |
||||
| AC CURRENT | 0.9A/115VAC 0.6A/230VAC | ||||||
| INRUSH CURRENT | COLD START 36A/230VAC | ||||||
| LEAKAGECURRENT | <2mA/240VAC | ||||||
| PROTECTION | OVERLOAD | 110~150% rated output power | |||||
| Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
| OVER VOLTAGE | YES | YES | |||||
| Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
| ENVIRONMENT | WORKING TIMP | -25~+70°C (Refer to “Derating Curve”) | |||||
| WORKINGHUMIDITY | 20~90% RH non-condensing | ||||||
| STORAGE TEMP HUMIDITY | -40~+85°C 10~95%RH | ||||||
| TEMPCOEFFICIENT | ±0.03%/ °C(0~50°C) on CH1 output | ||||||
| VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
| SAFETY&EMC | SAFETYSTANDARDS | U60950, TUV EN60950 approved | |||||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||
| ISOLATIONRESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||||
| EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | ||||||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | ||||||
| QTHERS | MTBF | 179Khrs min. MIL-HDBK-217F (25°C ) | |||||
| DIMENSION | 215*115*50mm (L*W*H) | ||||||
| PACKING | 0.95Kg; 20PCS/20Kg | ||||||
Applications:
Industrial control equipment, self-service terminal equipment, medical equipment, communication equipment, animation products, game consoles, beauty equipment, etc.
Applications for power supply
Packing & Delivery
Certifications
Product detail pictures:
Related Product Guide:
Just about every member from our large efficiency income crew values customers' wants and enterprise communication for Renewable Design for Power Supply 30v - DC 12V24V 600W Dual Output SMPS Power Supply – Huyssen , The product will supply to all over the world, such as: British, Maldives, Egypt, We always insist on the principle of "Quality and service are the life of the product". Till now, our products have been exported to more than 20 countries under our strict quality control and high level service.